+ RECORDING=/working/194070 + grep -Eqs ^[[:space:]]*-*min-redness[[:space:]]*(=|$) /working/194070/slapp.flags + echo min-redness=25 + [ -f /working/194070/slapp.flags ] + grep -Eq ^[[:space:]]*-*mmpp[[:space:]]*(=|$) /working/194070/slapp.flags + [ -n ] + CAMERA=--recording /working/194070 + python -m snapon_calibration mmpp /working/mmpp --recording /working/194070 --stick /working/stick/194070_Calibration.mp4 --flags /working/194070/slapp.flags --result /working/result.json 2026-11-05T08:10:20 - INFO: SnaponCalibration 0.0.1 2026-11-05T08:10:20 - INFO: camera calibration RCX90_SnapOn_2024-05-20 (id 103, in use from 2024-05-20T00:00:00+00:00) for camera rcx90, wand SnapOn 2026-11-05T08:25:05 - INFO: skipped 74 frames showing the OSD job card 2026-11-05T08:25:05 - INFO: stick found in 175 frames: {'vertical': 78, 'horizontal': 97, 'diagonal': 0} 2026-11-05T08:25:11 - WARNING: stick scale varies 1.1% between observations (10th-90th percentile): the stick moved in depth, so mmpp is an average over where it was held 2026-11-05T08:25:11 - WARNING: the stick's 0 mark is not in one place (orientations 110 mm apart, spread up to 29 mm), so it is not used as the bore centre 2026-11-05T08:25:12 - INFO: stick: mmpp 0.72123 through prj-n-processing-api-data/snapon/calibrations/laser/RCX90_SnapOn_2024-05-20 (tilt held at 0.0000, 0.0000 rad), 1.31 mm RMS (max 3.46) over 80 observations 2026-11-05T08:25:17 - INFO: set mmpp=0.721234 in /working/194070/slapp.flags 2026-11-05T08:25:17 - WARNING: finished with 2 warnings, see /working/mmpp/debug/3_fit